Daily start-up -7, Check torch -7, Daily start-up – Hypertherm HD4070 Rev.1 User Manual
Page 132
![background image](https://www.manualsdir.com/files/789619/content/doc132.png)
OPERATION
HyPerformance HD4070
Instruction Manual
4-7
Daily start-up
Prior to start-up, ensure that your cutting environment and clothing meet the safety requirements outlined in the
Safety section of this manual.
Check torch
1
1. Turn main disconnect switch to the power supply OFF.
2. Remove the consumables from the torch and check for worn or damaged parts. Always place the
consumables on a clean, dry, oil-free surface after removing. Dirty consumables can cause the torch to
malfunction.
• Refer to
Changing consumable parts later in this section for details and for parts inspection tables.
• Refer to the
Cut charts to choose the correct consumables for your cutting needs.
3. Replace consumable parts. Refer to
Changing consumable parts later in this section for details.
4. Ensure that the torch is perpendicular to the workpiece.
WARNING
Before operating this system, you must read the
Safety section thoroughly! Turn OFF the power
supply's main disconnect switch before proceeding with the following steps.
Retaining cap
Torch
Current ring
Electrode
Swirl ring
Nozzle
Shield
Inner retaining cap