Mild steel – Hypertherm HD4070 Rev.1 User Manual
Page 146

OPERATION
HyPerformance HD4070
Instruction Manual
4-21
Mild steel
O
2
Plasma / O
2
-N
2
Shield
130A Cutting
Pierce height = torch-to-work distance X pierce height factor
220173
220183
220176
220182
220179
220181
Metric
English
O2
N2
O2
N2
O2
N2
O2
N2
in
ipm
%
seconds
10/.135
124
0.100
240
0.1
3/16
126
190
0.2
1/4
127
150
5/16
129
130
3/8
130
110
7/16
131
95
0.4
1/2
132
80
0.5
9/16
134
70
0.6
5/8
135
60
0.7
40
90
3/4
140
45
1.0
12
35
19
58
200
0.3
0.110
0.120
0.130
0.150
Plasma
Shield
18
55
16
48
70
0
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
gauge/inch
Arc
Voltage
Torch-to-
Work
distance
Plasma
Shield
O2
N2
O2
N2
O2
N2
O2
N2
mm
mm/m
%
seconds
3
124
2.5
6400
0.1
4
126
5425
0.2
5
127
4700
6
127
3975
8
129
3325
10
130
2650
12
132
3.2
2175
0.5
15
135
1650
0.7
40
90
20
140
1025
1.0
200
0.3
2.7
3.0
3.7
16
48
12
35
70
0
19
58
18
55
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
millimeters
Arc
Voltage
Plasma
Shield
Plasma
Shield
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay