Cable – gas console to ignition console b-11 – Hypertherm HD4070 Rev.1 User Manual
Page 111

2-TORCH INSTALLATION
HyPerformance HD4070
Instruction Manual
3B-11
Cable – gas console to ignition console
16
Part no.
Length
123446
3 m (10 ft)
123447
6 m (20 ft)
123448
7.5 m (25 ft)
123449
9 m (30 ft)
123450
12 m (40 ft)
Part no.
Length
123512
15 m (50 ft)
123559
18 m (60 ft)
123513
23 m (75 ft)
123514
30.5 m (100 ft)
CABLE RUN LIST
Signal name
2X1
Color
3X3/4
Function
Input/Output
Not used
13
Grey
13
Not used
25
Brown
25
Not used
12
Red
12
Not used
24
Yellow
24
Not used
11
Red
11
Not used
23
Blue
23
Not used
10
Red
10
Not used
22
Green
22
Not used
9
Red
9
Not used
21
White
21
Not used
8
Red
8
Not used
20
Orange
20
Not used
7
Black
7
Vent-120 VAC return
19
Brown
19
Energizes the vent solenoid
Output
Vent-120 VAC
6
Black
6
Output
Plasma cutflow-120 VAC return
18
Yellow
18
Energizes the plasma cutflow solenoid
Output
Plasma cutflow-120 VAC
5
Black
5
Output
Plasma preflow-120 VAC return
17
Blue
17
Energizes the plasma preflow solenoid
Output
Plasma preflow-120 VAC
4
Black
4
Output
Shield cutflow-120 VAC return
16
Green
16
Energizes the shield cutflow solenoid
Output
Shield cutflow-120 VAC
3
Black
3
Output
Shield preflow-120 VAC return
15
White
15
Energizes the shield preflow solenoid
Output
Shield preflow-120 VAC
2
Black
2
Output
Ignitor-120 VAC return
14
Red
14
Energizes the ignitor
Output
Ignitor-120 VAC
1
Black
1
Output
2X1
3X3/4