Mild steel – Hypertherm HD4070 Rev.1 User Manual
Page 145

OPERATION
4-20
HyPerformance HD4070
Instruction Manual
Mild steel
O
2
Plasma / O
2
-N
2
Shield
80A Cutting
Pierce height = torch-to-work distance X pierce height factor
220173
220189
220176
220188
220179
220187
Metric
English
O2
N2
O2
N2
O2
N2
O2
N2
in
ipm
%
seconds
14/.075
112
400
12/.105
115
290
10/.135
117
180
3/16
119
155
1/4
121
110
0.3
5/16
123
92
0.4
3/8
124
75
0.5
7/16
125
62
0.6
1/2
126
50
0.7
150
200
250
0.1
0.2
0.100
0.080
34
0
10
24
11
48
11
34
15
52
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
gauge/inch
Arc
Voltage
Plasma
Shield
Plasma
Shield
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay
O2
N2
O2
N2
O2
N2
O2
N2
mm
mm/m
%
seconds
2
112
9650
0.1
3
117
6050
4
119
4225
5
120
3600
6
121
3000
8
123
2000
0.4
10
124
1775
0.5
11
34
12
126
1400
250
0.7
34
0
10
24
15
52
0.2
150
200
11
48
2.5
2.0
0.3
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
millimeters
Arc
Voltage
Plasma
Shield
Plasma
Shield
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay