Connect the power -15, Connect the power – Hypertherm HD4070 Rev.1 User Manual
Page 67
![background image](https://www.manualsdir.com/files/789619/content/doc067.png)
INSTALLATION
HyPerformance HD4070
Instruction Manual
3-15
4070.02
L1 L2
L3
GND
Connect the power
Note:
Connect main power cable last if installing THC cables, for ease of installation.
1. Insert the power cable through the strain relief at the rear of the power supply.
2. Connect the ground lead (PE) to the GND terminal of TB1 as shown below.
3. Connect the power leads to the terminals of TB1 as shown below.
4. Check that the line disconnect switch is in the OFF position and remains in the OFF position for the
remainder of the installation of the HD4070 system.
5. Connect the power cord leads to the line disconnect switch following national or local electrical codes.
L1 = Black
L2 = White
L3 = Red
GND = Green / earth ground
WARNING
ELECTRICAL SHOCK CAN KILL
The line disconnect switch must be in the OFF position before making the power cable connections.
In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries, follow
appropriate national or local safety procedures.
Line
disconnect
switch
Power
cable
TB1