Aluminum – Hypertherm HD4070 Rev.1 User Manual
Page 153

OPERATION
4-28
HyPerformance HD4070
Instruction Manual
Aluminum
H35-N
2
Plasma / N
2
Shield
130A Cutting
Pierce height = torch-to-work distance X pierce height factor
220173
220198
220304
220197
220179
220307
Metric
English
H35
N2
H35
N2
H35
N2
H35
N2
in
ipm
%
seconds
1/4
156
85
5/16
158
75
3/8
159
65
7/16
159
0.130
60
0.4
1/2
160
55
0.5
9/16
161
52
0.7
5/8
162
45
0.8
3/4
164
35
1.3
0.120
0
31
25
43
0
80
0.3
0
65
0.140
Pierce
Delay
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
inch
Arc
Voltage
Plasma
Shield
Plasma
Shield
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
200
H35
N2
H35
N2
H35
N2
H35
N2
mm
mm/m
%
seconds
6
156
2125
8
158
1875
10
159
1625
12
160
1375
0.5
15
162
1125
0.8
20
164
875
1.3
0
0
80
3.0
25
43
Torch-to-
Work
distance
0
31
65
3.5
0.3
200
Arc
Voltage
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay
Plasma
Shield
Plasma
Shield
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
millimeters