System operation screens -11, System operation screens 4 – Hypertherm HD4070 Rev.1 User Manual
Page 136
![background image](https://www.manualsdir.com/files/789619/content/doc136.png)
OPERATION
HyPerformance HD4070
Instruction Manual
4-11
TORCH 1
PURGING
STAINLESS STEEL
AUTO
MAN
THC
ARC
VOLT
ARC
VOLT
3/4 IN
200 AMPS
++
_ _
13
CNC
TORCH 1
NO PILOT ARC
STAINLESS STEEL
AUTO
MAN
THC
ARC
VOLT
ARC
VOLT
3/4 IN
200 AMPS
++
_ _
13
CNC
TORCH 1
READY
STAINLESS STEEL
AUTO
MAN
THC
ARC
VOLT
ARC
VOLT
3/4 IN
200 AMPS
++
_ _
13
NEXT
NEW
PROCESS
NEXT
NEW
PROCESS
NEXT
NEW
PROCESS
TRAVEL SPEED: 84 IPM
INLET GAS: O2 N2
CUT HEIGHT: 0.180 IN
SET ARC VOLTS: 161.0 V
TRAVEL SPEED: 84 IPM
INLET GAS: O2 N2
CUT HEIGHT: 0.156 IN
SET ARC VOLTS: 144.0 V
TRAVEL SPEED: 84 IPM
INLET GAS: O2 N2
CUT HEIGHT: 0.156 IN
SET ARC VOLTS: 144.0 V
System operation screens
4
When screen 13 first appears, the system will
purge all gas lines.
After the gases are purged, the screen will display
READY indicating that the power supply is ready to
receive the start signal from the CNC.
Screen 13 provides process information so that the
operator can view what parameters are being used.
Error codes are displayed at the top of the screen.
The system will clear some error codes and will then
return to the READY state. When an error occurs
that freezes the system software, a RESET button
appears in place of NEW PROCESS. Pushing
RESET clears the error without having to turn the
power off.
See
Maintenance Section 5 for a complete list of
error codes and corrective actions.
Display will advance to screen 14.