Plasma interface board pcb5 status indicators -22 – Hypertherm HD4070 Rev.1 User Manual
Page 185
5-22
HyPerformance HD4070
Instruction Manual
MAINTENANCE
Plasma interface board PCB5 status indicators
J 4
J 8
T P 4
J 7
J 6
J 2
J 3
J 1
Plasma interface PC board LED list
LED
Signal name
Function
D2
+24 Volts
Power indicator, Always ON
D7
Ohmic Contact
Illuminates when torch is in contact with plate
D9
Transfer
Illuminates when arc transfers to plate
D10
Shield #1
Relay for THC #1. ON when circuit is closed
D12
Cooling Temp OK
Coolant temperature at acceptable level, always ON
D13
Spare Input
Not used
D14
+15 Volts
Power indicator, Always ON
D15
Shield #2
Relay for THC #2. ON when circuit is closed
D17
Cooling Flow OK
Sensor detecting good coolant flow
D18
Spare Output
Not used
D20
-15 Volts
Power indicator
This manual is related to the following products: