Hypertherm HD4070 Rev.1 User Manual
Page 143
![background image](https://www.manualsdir.com/files/789619/content/doc143.png)
OPERATION
4-18
HyPerformance HD4070
Instruction Manual
Marking
N
2
or H5 Plasma / N
2
Shield
220173
220202
220304
220201
220180
220308
Gas Rate Gas Rate Gas Rate Gas Rate
Amps
mm
mm/m
Mild Steel
N2
15
N2
40
N2
15
N2
40
7
153.0
6250
Stainless Steel
H5
50
N2
80
H5
40
N2
80
7
84.0
3000
Aluminum
H5
50
N2
80
H5
20
N2
80
10
78.0
4375
2.2
Test Preflow Rate (%)
Plasma
Shield
Material
Torch-to-
Work
Distance
Cutting
Speed
Arc
Voltage
Test Cutflow Rate (%)
Plasma
Shield
Marking
Current
Metric
English
Gas Rate Gas Rate Gas Rate Gas Rate
Amps
in
ipm
Mild Steel
N2
15
N2
40
N2
15
N2
40
7
153.0
250
Stainless Steel
H5
50
N2
80
H5
40
N2
80
7
84.0
120
Aluminum
H5
50
N2
80
H5
20
N2
80
10
78.0
175
0.090
Material
Test Preflow Rate (%)
Test Cutflow Rate (%)
Plasma
Shield
Plasma
Cutting
Speed
Torch-to-
Work
Distance
Arc
Voltage
Marking
Current
Shield