Mild steel – Hypertherm HD4070 Rev.1 User Manual
Page 144

OPERATION
HyPerformance HD4070
Instruction Manual
4-19
Mild steel
O
2
Plasma / O
2
-N
2
Shield
30A Cutting
Pierce height = torch-to-work distance X pierce height factor
220173
220194
220313
220193
220180
220192
Metric
English
O2
N2
O2
N2
O2
N2
O2
N2
mm
mm/m
%
seconds
16
16
1
110
1.2
3550
0.3
23
2
120
1475
0.4
3
124
1150
0.5
4
900
0.7
5
775
0.9
6
650
1.0
10
13
12
127
180
34
0
10
32
0
0
1.5
O2
N2
O2
N2
O2
N2
O2
N2
in
ipm
%
seconds
26/.018
110
215
24/.024
110
200
22/.030
110
170
0.2
20/.036
110
155
18/.048
114
110
16/.060
117
85
14/.075
120
60
12/.105
122
50
10/.135
124
40
0.5
3/16
127
30
0.7
1/4
127
25
1.0
0.1
0.3
0.4
10
13
16
180
0
32
10
0.050
0.060
34
23
12
0
16
0
Test Preflow Rate (%)
Plasma
Shield
Test Cutflow Rate (%)
Plasma
Shield
Material
Thickness
gauge/inch
Arc
Voltage
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay
Test Preflow Rate (%)
Test Cutflow Rate (%)
Material
Thickness
millimeters
Arc
Voltage
Torch-to-
Work
distance
Cutting
Speed
Pierce
Height
Factor
Pierce
Delay
Plasma
Shield
Plasma
Shield