4.10.2 Remounting
STEP 3
Check that the bearing (#3-5) is seated firmly in 
the actuator housing. 
3
STEP 4
NOTE: Lightly lubricate the O-ring (#3-7) before remounting worm shaft (subassembly #3).
Lightly lubricate the O-ring (#3-7) on the worm 
shaft (subassembly #3). Push the complete 
worm shaft assembly into the actuator housing 
until the worm contacts the worm gear. Turn 
the worm so it engages the worm gear and 
continue rotating until the end of the worm 
shaft is isolated in the inboard bearing (#3-4).
MX-85, -140, AND -150 ONLY
Be sure the motor wiring harness is pushed 
in, then rotate worm shaft cap (#3-2) around 
so that tab is holding wiring harness in place. 
See Section 5.11 for motor wiring harness 
installation.
4a
3-7
4b
Motor
wiring
harness