61
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 1
c
WARNING: Potential to operate while dangerous mechanical parts are exposed during 
subassembly removal. To prevent injury, turn off all power sources to actuator before 
removing base plate assembly. Power sources may include main power or control 
power. 
Using a hex key, remove the four or eight 
screws (#11-5).
1
11-5
STEP 2
c
WARNING: MX-85, -140, and -150. If handwheel worm gear assembly has previously 
been removed, the drive sleeve assembly may slip and fall out of housing. Hold drive 
sleeve assembly in from opposite end. See Section 4.12.1 and 4.12.2 for optional 
removal and remounting.
Pull the baseplate (#11-1) off the drive sleeve.
2a
11-1
2b