Flowserve MX Limitorque User Manual
Page 69
61
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 1
c
WARNING: Potential to operate while dangerous mechanical parts are exposed during
subassembly removal. To prevent injury, turn off all power sources to actuator before
removing base plate assembly. Power sources may include main power or control
power.
Using a hex key, remove the four or eight
screws (#11-5).
1
11-5
STEP 2
c
WARNING: MX-85, -140, and -150. If handwheel worm gear assembly has previously
been removed, the drive sleeve assembly may slip and fall out of housing. Hold drive
sleeve assembly in from opposite end. See Section 4.12.1 and 4.12.2 for optional
removal and remounting.
Pull the baseplate (#11-1) off the drive sleeve.
2a
11-1
2b
This manual is related to the following products: