119
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 9
Insert the terminal block into the terminal block 
mounting cavity.
9
STEP 10
Insert the retaining ring (#1-21) into the 
retaining ring groove - snap the retaining 
ring into the groove by working a flat blade 
screwdriver around the edge of the retaining 
ring until it seats into the groove.
10
1-21
STEP 11
If the contactor assembly was loosened in 
Step 7, then remount the contactor on screws 
(#8-28). Retighten with M3 hex key.
11
STEP 12 AND 13
Connect the incoming power leads and the 
control wiring according to the application 
wiring diagram if the terminal block has been 
replaced.
Install the terminal compartment cover and 
secure with four M8 screws using a 6 mm hex 
key.
12, 13