Flowserve MX Limitorque User Manual
Page 114

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
106
STEP 5
Position the power assembly over the three 
mounting screw heads (#1-45). Rotate the 
subassembly in the clockwise (CW) direction 
until all three screws are seated in the key 
slots. (The keyhole slots in the mounting plate 
(#8-1) are spaced in such a way that the control 
module assembly will mount in only one 
position).
Tighten the three screws (#1-45) with a 3 mm 
hex key.
5
STEP 6
Connect the AMP power connector to the fuse 
section on the power board (P1). 
6
STEP 7
Connect the 10-pin encoder ribbon cable to 
plug P3 on the Main/LCS processor board. 
Align the polarization plug with the slot in the 
center of connector J1.
7
STEP 8
Connect the 4-pin Molex harness to plug P4 on the Main/LCS processor board.
STEP 9
If DDC, F
oundation
Fieldbus H1 or PROFIBUS
DP/PA board is installed, stack the network 
board onto the Main/LCS board (or I/O option 
board) assuring proper mating of the board-
to-board connector P1. Connect 10-pin Molex 
harness to plug P2 on these boards (network 
processor board). 
9