Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
124
STEP 5
Route leads L1, L2, and L3 (input power) to the 
terminal block cavity.
MX-05, -10, -20 AND -40 ONLY
Feed the motor power plug through the 
housing to the motor cavity. 
MX-85, -140, AND -150 ONLY
Reconnect connectors 4 and 5 to the motor 
lead harness.
5a
Motor Cavity
Terminal Block
Cavity
Motor Power
Plug
5b
STEP 6
Leave the contactor assembly unmounted in 
the control module compartment to allow space 
for the terminal block harness plug bundle to be 
threaded over the top of the contactor assembly 
and pulled into the control module cavity.
6
STEP 7
Reference the terminal block assembly proce-
dures to remount the terminal block assembly 
into actuator. (See Section 5.8.2.)
Before mounting the contactor assembly, 
ensure the terminal block wiring harness 
bundle is positioned across the end of the 
contactor.
7
Terminal Block
Wiring Bundle