WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.COM WWW.FIELDPIECE.CO

5.1

“CheckMe!®” (HG2 Only)

3

CheckMe!®

” is the most advanced real-world

method for troubleshooting A/C systems. It looks at the
big picture to diagnose problems. Superheat, Subcooling,
and Target Evaporator Exit Temperature tests look at in-
dividual performance indicators to determine if they are
within proper range.

CheckMe!®

looks at the system as

a whole to give a more complete diagnosis.

CheckMe!®

saves time and money by quickly diagnosing a range of
problems or even multiple problems.

CheckMe!®

rec-

ommends actions to tune the air conditioning system
to its optimum with minimal retests. Th

is leads to even

fewer call backs.

Th

e algorithms built into CheckMe!® are based

on the real world servicing of over 150,000 air con-
ditioners. Th

e testing procedure and accuracy of the

diagnosis have been refi ned over many years by Proc-
tor Engineering. Th

e CheckMe!® switch position is a

real time-saver because it can give you a more accurate
diagnosis than looking at individual aspects of the air
conditioner.

Th

e CheckMe!® has 35 diagnoses which will help

you pinpoint the problem with the air conditioning
system. In addition to giving you better diagnoses, the
CheckMe!® test will ensure that you have fi lled in the
form completely and warns you if conditions are un-
likely to exist or impossible. In these cases, you will
want to retake some measurements.

CheckMe!® will analyze the system with almost any

amount of data. Th

e more information supplied to the

program, the more accurate and comprehensive the di-
agnosis. CheckMe!® determines the current state of the
equipment. Th

erefore you can pretest equipment prior

to any repairs.

3 CheckMe!® is the registered trademark of Proctor Engineering Group, Ltd.

5.2 CheckMe!® INPUT FORM Overview

Figure 20. CheckMe!® INPUT FORM.

Th

e quickest way to an optimized system will be to

clean coils and fi lters prior to the initial test. Th

en com-

pletely fi ll out the the CheckMe!® INPUT FORM for a
more comprehensive and accurate diagnosis of the sys-
tem.

General Information: The type of

system and the nominal tonnage.

Can be measured automatically with

Fieldpiece accessory heads.

True Flow: The measurements are

only visible if you select Yes for True

Flow. These are manual inputs.

Customer ID is useful for record

keeping.

Grant: These are all manual inputs

which are used for record keeping

when participating in a grant

program or third party verification.

Units can be changed to either

English or Metric.