Fieldpiece LT17A - Digital Multimeter User Manual
User maintenance, For your safety, Symbols used
DIGITAL MULTIMETER
Model: LT17A
OPERATOR’S MANUAL
General description
The LT17A is designed for the HVAC/R techni-
cian. The LT17A meter measures current, resist-
ance, voltage, capacitance, frequency, continuity,
and temperature. Test leads store within the meter
and can connect the LT17A to Fieldpiece accesso-
ry heads. The body is made out of durable ABS
plastic and comes with a bright blue backlight for
poorly lit test areas. Get great accuracy with the k-
type thermocouple and easily accessible temp. pot.
User maintenance
Battery Replacement:
When the multimeter dis-
plays the " " the battery must be replaced to
maintain proper operation. To prevent electrical
shock, turn off the meter and disconnect leads
before removing the back cover.
Fuse Replacement
: When only certain ranges
quit working, check the fuse. Open the case and
replace according to the Overload Protection chart.
All other repairs must be performed by a
Fieldpiece service center.
For your safety...
General:
Inspect the test leads for damage to the
insulation or exposed metal. Replace if suspect. Never
ground yourself when taking electrical measurements.
Do not touch exposed metal pipes, outlets, fixtures,
etc., which might be at ground potential. Keep your
body isolated from ground by using dry clothing, rubber
shoes, rubber mats, or any approved insulating materi-
al. When disconnecting from a circuit, disconnect the
"RED" lead first, then the common lead. Work with oth-
ers. Use one hand for testing. Turn off power to the cir-
cuit under test before cutting, unsoldering, or breaking
the circuit. Keep your fingers on the plastic and behind
the ridge of the probes.
All Voltage Tests:
All voltage ranges will with-
stand up to 600VAC or 600VDC. Do not apply more
than 600VDC or 600VAC.
AC Tests:
Disconnect the meter from the circuit
before turning any inductor off, including motors,
transformers, and solenoids. Hi voltage transients
can damage the meter beyond repair. Do not use
during electrical storms.
Safety:
Designed to meet IEC 61010-1
(EN61010-1), CATIII 600V, Class II, pollution deg.2,
indoor use and complies with CE. C-Tick certified.
Symbols used:
Caution, refer to manual.
Ground
Double insulation
Overload protection
Service
Call Fieldpiece Instruments for one-price-fix-all
warranty service pricing. Send check or money
order for the amount quoted. Send the meter freight
prepaid to Fieldpiece Instruments. Send proof of
date and location of purchase for in-warranty serv-
ice. The meter will be repaired or replaced, at the
option of Fieldpiece, and returned via least cost
transportation.
www.fieldpiece.com
MAX
MI N
General Specifications
Auto-off:
off after 25 minutes to extend battery.
Indicators:
Continuity beeper (<100
Ω). Low bat.
Overrange:
"OL" or “-OL” is displayed.
Operating environment:
32 to 122°F (0 to 50°C)
<70%RH
Storage environment (with batteries removed):
-4 to 140°F (-20 to 60°C) <80%RH
Altitude:
6561.7 feet (2000m).
Battery life:
150 hours typical.
Battery type:
9V NEDA 1604 type
Stated accuracies:
74°F±8°F (23°C±4°C),
75%RH
Temperature coefficient:
0.1 x (specified accura-
cy)1°F/°C (32 to 66°F (0 to 19°C), 82 to 122°F
(28 to 50°C)).
DC Voltage
Ranges:
200mV, 2000mV, 20V, 200V, 600V
Resolution:
0.1mV
Accuracy:
0.5%±1
Input impedence:
10M
Ω
AC Voltage
(50Hz-500Hz)
Ranges:
200mV, 2000mV, 20V, 200V, 600V
Resolution:
0.1mV
Accuracy:
1.2%±4(200mV to 20V ranges),
2%±4(200V and 600V ranges)
Input impedence:
10M
Ω
DC Current
(through meter)
Ranges:
200μA, 20mA, 200mA
Resolution:
0.1μA
Accuracy:
1.0%±1
Voltage burden:
800mV
AC Current
(through meter)
Ranges:
200μA, 20mA, 200mA
Resolution:
0.1μA
Accuracy:
1.5%±4
Voltage burden:
800mV
Frequency
(autoranging)
Range:
10Hz to 40KHz
Resolution:
1Hz
Sensitivity:
3.5V rms min
Accuracy:
0.1%± 3
Resistance
(ohms)
Ranges:
200
Ω, 2kΩ, 200kΩ, 20MΩ
Resolution:
0.1
Ω
Accuracy:
1.0%±4 (200
Ω to 200kΩ ranges),
2.0%±4 (20M
Ω range)
Open circuit voltage:
0.3VDC typical, (3.0VDC
on 200
Ω)
Diode Test
Accuracy:
1.5%±3
Test current:
1.0mA approx.
Open circuit voltage:
3.0VDC typical
Capacitance
(MFD)
Ranges:
200μF, 2kμF, 20kμF
Resolution
: 0.1μF
Accuracy:
4%±10
Test frequency:
21Hz
Test voltage:
<3.0V
Temperature
Ranges:
-30 to 1400°F (-34 to 750°C)
Resolution:
0.1°F/°C
Accuracy:
±1°F; 32 to 120°F (±0.5°C; 0 to 48°C),
±1.0%+1.5°F; -4 to 750°F (±1.0%+1.0°C; -20 to
399°C)
±3.0%+4°F; -30 to -4°F and 750 to 1400°F
(±3.0%+2°C; -34 to -20°C and 399 to 750°C)
Sensor type:
K-type thermocouple
Field Calibration
(temp offset pot)
The LT17A can be easily calibrated on the job.
Use a bucket of ice water to have a known 32°F
(0°C) temperature. With the thermocouple in the ice
water, adjust the TEMP OFFSET pot on the face of
the meter until it reads 32.0 (0.0).
MAX/MIN
Record the minimum or maximum reading during
a measurement. To exit the MIN/MAX function, hold
the button for more than 2 seconds.
Backlight
Always be very careful when testing in the dark.
You should always have a separate light on the
area you are testing. The backlight will shine for 4.5
minutes when the backlight button is pressed.
Limited warranty
This meter is warranted against defects in mate-
rial or workmanship for one years from date of pur-
chase. Fieldpiece will replace or repair the defective
unit, at its option, subject to verification of the
defect.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising from the sale of a
Fieldpiece product, including but not limited to
implied warranties of merchantability and fitness for
a particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the
instrument or other incidental or consequential
damages, expenses, or economic loss, or for any
claim of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclu-
sions may not apply to you.
>200mV range 600VAC/DC rms
Temperature
30VAC/DC rms
Frequency
500VAC/DC rms
Resistance
500VAC/DC rms
Diode Test
500VAC/DC rms
Continuity
500VAC/DC rms
600VAC/DC rms
for 15 sec
0.25A/500V fuse
(6.3X32mm)
model RFM66
0.25A/500V fuse
(6.3X32mm)
model RFM66
200mV range
VAC/DC
AAC/DC
Capacitance
!