Fieldpiece ARH5 - Psychrometer Accessory Head User Manual

Fieldpiece, Quick start, Certifications

background image

01

01

03

03

06

06

02

02

05

05

04

04

Quick Start

1. Connect ARH5 to Fieldpiece meter.

2. Select mVDC range on meter.

3. Remove vinyl slip cover from the

probe tip.

4. Select desired switch position on

ARH5 for temperature, wet bulb,

dew point, or %RH.

5. Read your measurement directly on

the display of the Fieldpiece meter.

Certifications

C-Tick (N22675)

CE

RoHS compliant

Description

With your purchase of the ARH5 you

now have the ability to take supply/

return temperature, %RH, wet bulb

and dew point measurements from

inside the duct or plenum.

Use the telescopic probe to take

measurements in hard to reach places.

Yo u r A R H 5 m e a s u re s b o t h

relative humidity and ambient

air temperature. It also calculates

dew point and wet bulb temperatures

automatically.

The ARH5 snaps directly onto

Fieldpiece HS series DMMs, Fieldpiece

Datalogger or HVAC Guide® System

Analyzer. For other meters, use

Fieldpiece ADLS2 test leads or the

AHDL1 handle adapter.

Use your ARH5 in combination with

the HVAC Guide and easily perform

Target Evaporator Exit Temperature

tests and get more reliable and

convenient Target Superheat

calculations.

Fieldpiece

In-Duct

Psychrometer

Head

OPERATOR'S

MANUAL

Model ARH5

Specifications

Telescoping Probe Length: Up to 38 inches (97cm)

Probe Tip Diameter: 0.35 inch (9mm)

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0

to 80% RH (with battery removed)

Temperature Coefficient: 0.1 x (specified accuracy)/°C

(<18°C or >28°C)

Power: Single standard 9-volt battery, NEDA 1604, JIS

006P, IEC 6F22

Auto Power Off: Approx. 15 minutes

Battery life: 150 hours typical (alkaline)

Low Battery Indication: Red LO BATT LED will light to

indicate low battery.

Output Impedance: 500Ω approx.

Dimensions: 144mm(H) x 67mm(W) x 32mm(D)

Weight: Approx. 240g, including battery

Temperature:

Sensor type: Precision thermistor

Operating environment: -4°F to 140°F (-20°C to 60°C)

Range: -4°F to 140°F (-20°C to 60°C)

Resolution: 0.1°F / 0.1°C

Accuracy: ±(1°F) 32°F to 113°F

±(2°F) -4°F to 32°F, 113°F to 140°F

±(0.5°C) 0°C to 45°C

±(1°C) -20°C to 0°C, 45°C to 60°C

Output: 1mV to 1°F/°C

Relative Humidity:

Sensor Type: Capacitance polymer film

Operating environment: 32°F to 131°F (0°C to 55°C)

Range: 0% to 100%RH

Accuracy: ±(2.5%) 10% to 90%RH

±(5%) <10%RH and >90%RH

Note: Above accuracies stated at 73.4°F (23°C).

Output: 1mV to %RH

Sensor Response Time: 60 seconds typical for 90% of

total range.

Sensor Hystersis: ±1%RH typical (Excursion of 10% to

90% to 10%RH)

80

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

OFF

2000

2

2000

00

ET2W

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEAD!

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

FUSED

200

mA

MAX

FUSED

30V

MAX

WIRELESS

ENABLED

MAX/MIN

SYNC

HOLD

CAT.III

MAX

600V

15 SEC FOR

500

mV

RANGE

AUTO-OFF

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2K

200

20M

2K

200K

20

RECV

WARNING

Do not retract the sensor probe by pulling on the cord.

Doing so may sever the cord from the sensors.

Quick Start

1. Connect ARH5 to Fieldpiece meter.

2. Select mVDC range on meter.

3. Remove vinyl slip cover from the

probe tip.

4. Select desired switch position on

ARH5 for temperature, wet bulb,

dew point, or %RH.

5. Read your measurement directly on

the display of the Fieldpiece meter.

Certifications

C-Tick (N22675)

CE

RoHS compliant

Fieldpiece

In-Duct

Psychrometer

Head

OPERATOR'S

MANUAL

Model ARH5

80

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

WARNING

Do not retract the sensor probe by pulling on the cord.

Doing so may sever the cord from the sensors.

Specifications

Telescoping Probe Length: Up to 38 inches (97cm)

Probe Tip Diameter: 0.35 inch (9mm)

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0

to 80% RH (with battery removed)

Temperature Coefficient: 0.1 x (specified accuracy)/°C

(<18°C or >28°C)

Power: Single standard 9-volt battery, NEDA 1604, JIS

006P, IEC 6F22

Auto Power Off: Approx. 15 minutes

Battery life: 150 hours typical (alkaline)

Low Battery Indication: Red LO BATT LED will light to

indicate low battery.

Output Impedance: 500Ω approx.

Dimensions: 144mm(H) x 67mm(W) x 32mm(D)

Weight: Approx. 240g, including battery

Temperature:

Sensor type: Precision thermistor

Operating environment: -4°F to 140°F (-20°C to 60°C)

Range: -4°F to 140°F (-20°C to 60°C)

Resolution: 0.1°F / 0.1°C

Accuracy: ±(1°F) 32°F to 113°F

±(2°F) -4°F to 32°F, 113°F to 140°F

±(0.5°C) 0°C to 45°C

±(1°C) -20°C to 0°C, 45°C to 60°C

Output: 1mV to 1°F/°C

Relative Humidity:

Sensor Type: Capacitance polymer film

Operating environment: 32°F to 131°F (0°C to 55°C)

Range: 0% to 100%RH

Accuracy: ±(2.5%) 10% to 90%RH

±(5%) <10%RH and >90%RH

Note: Above accuracies stated at 73.4°F (23°C).

Output: 1mV to %RH

Sensor Response Time: 60 seconds typical for 90% of

total range.

Sensor Hystersis: ±1%RH typical (Excursion of 10% to

90% to 10%RH)

OFF

2000

2

2000

00

ET2W

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEAD!

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

FUSED

200

mA

MAX

FUSED

30V

MAX

WIRELESS

ENABLED

MAX/MIN

SYNC

HOLD

CAT.III

MAX

600V

15 SEC FOR

500

mV

RANGE

AUTO-OFF

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2K

200

20M

2K

200K

20

RECV

Description

With your purchase of the ARH5 you

now have the ability to take supply/

return temperature, %RH, wet bulb

and dew point measurements from

inside the duct or plenum.

Use the telescopic probe to take

measurements in hard to reach places.

Yo u r A R H 5 m e a s u re s b o t h

relative humidity and ambient

air temperature. It also calculates

dew point and wet bulb temperatures

automatically.

The ARH5 snaps directly onto

Fieldpiece HS series DMMs, Fieldpiece

Datalogger or HVAC Guide® System

Analyzer. For other meters, use

Fieldpiece ADLS2 test leads or the

AHDL1 handle adapter.

Use your ARH5 in combination with

the HVAC Guide and easily perform

Target Evaporator Exit Temperature

tests and get more reliable and

convenient Target Superheat

calculations.

Go wireless with your ARH5 by

using Fieldpiece wireless transmitters

(ET2W/EH4W) to send measurements

over-the-air to Fieldpiece wireless

receivers (HG3, LT17AW, EH4W )

anywhere on the jobsite.

ARH5 w/ ET2W

transmitting wirelessly to HG3

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

Clear

Input

Output

Recall

Enter

Save

Sync

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

HVAC Guide

CheckMe!

Fieldpiece HG3

Data

Service

E

Exit T

Ex

Ex

E

e

Target

arget

arget

rget

rget

get

Targe

or

ator

ato

ator

ator

ator

Ta

Evaporat

t Temp

INPUT FORM

SH Table: Standard

Refrigerant: R-22

OD Dry Bulb:

85.4°F

Return WB:

63.0°F

SL Pressure:

52.4psig

SL Temp:

45.4°F

CustomerID: __JONES123

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

Clear

Input

Output

Recall

Enter

Save

Sync

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

HVAC Guide

CheckMe!

Fieldpiece

HG3

Data

Service

E

Exit T

Ex

Ex

E

e

Target

arget

arget

rget

rget

get

Targe

or

ator

ato

ator

ator

ator

Ta

Evaporat

t Temp

INPUT FORM

SH Table: Standard

Refrigerant: R-22

OD Dry Bulb:

85.4°F

Return WB:

63.0°F

SL Pressure:

52.4psig

SL Temp:

45.4°F

CustomerID:

__JONES123

Use the RCONE1 for hands-free

in-duct measurements.

Figure 1

Go wireless with your ARH5 by

using Fieldpiece wireless transmitters

(ET2W/EH4W) to send measurements

over-the-air to Fieldpiece wireless

receivers (HG3, LT17AW, EH4W )

anywhere on the jobsite.

ARH5 w/ ET2W

transmitting wirelessly to HG3

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

Clear

Input

Output

Recall

Enter

Save

Sync

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

HVAC Guide

CheckMe!

Fieldpiece HG3

Data

Service

E

Exit T

Ex

Ex

E

e

Target

arget

arget

rget

rget

get

Targe

or

ator

ato

ator

ator

ator

Ta

Evaporat

t Temp

INPUT FORM

SH Table: Standard

Refrigerant: R-22

OD Dry Bulb:

85.4°F

Return WB:

63.0°F

SL Pressure:

52.4psig

SL Temp:

45.4°F

CustomerID: __JONES123

ARH5

In-Duct

Psychrometer

Head

ON

AUTO OFF

1%RH/mVDC

1°F/mVDC

1°C/mVDC

LO BATT

DEW POINT

%RH

WET BULB

TEMP

°F

°C

ON

OFF

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

Clear

Input

Output

Recall

Enter

Save

Sync

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

HVAC Guide

CheckMe!

Fieldpiece

HG3

Data

Service

E

Exit T

Ex

Ex

E

e

Target

arget

arget

rget

rget

get

Targe

or

ator

ato

ator

ator

ator

Ta

Evaporat

t Temp

INPUT FORM

SH Table: Standard

Refrigerant: R-22

OD Dry Bulb:

85.4°F

Return WB:

63.0°F

SL Pressure:

52.4psig

SL Temp:

45.4°F

CustomerID:

__JONES123

Use the RCONE1 for hands-free

in-duct measurements.

Figure 1