Quick Start

1. For electrical testing, connect test leads to

"COM" and "+" jacks. For temperature testing,

remove test leads and slide TEMP switch to

the right.

2. Rotate the dial to your desired function. Press

SEL to cycle through the parameters within

the switch position.

3. Connect to test points and read measurement

on display.

Certifications

UL 61010-1, Second Edition

IEC/EN61010-1

IEC/EN61010-2-032

EMC EN61326-1

C-Tick (N22675)

WEEE

CATIII 600V, class II and pollution degree 2

indoor use comply with CE, RoHS compliant.

Description

Your SC54 is a swivel clamp meter specially

designed for the HVACR technician. The swivel

on the SC54 allows you to get a good viewing

angle on the display while taking amperage

readings through the clamp, regardless of the

wire orientation. The SC54 has the functions

you want as an HVACR technician.

Get fast manual ranging performance on an

easy to use auto-ranging clamp meter.

The SC54 is compatible with Fieldpiece

accessory heads allowing you to measure many

parameters on the SC54 display.

The bright blue backlight

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

makes it easier

to use in any lighting condition. True RMS helps

you take more accurate voltage and amperage

readings on variable frequency drives.

The unique temperature circuit allows the

SC54 to get accurate temperature readings

faster when moving from a rooftop to a freezer.

The easily accessible field calibration allows

you to calibrate the temperature on your SC54

without hassle.

Controls

Rotate dial to the function you want to use.

Cycle through parameters or ranges

within a dial position

Press to illuminate backlight for 3 min

Press to freeze maximum or minimum

reading

Press to freeze the reading

Fieldpiece

Swivel

Clamp

Meter

OPERATOR'S

MANUAL

Model SC54

Display

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

Battery Life Indicator

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Auto Power Off Enabled

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

High Voltage Warning (+30V)

Manual Ranging

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

Data Hold Mode

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

Maximum Reading

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

Minimum Reading

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Continuity Test

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Frequency Test (hertz)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Resistance Test (ohms)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Capacitance Test (farads)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Micro Unit (10

−6

, one millionth)

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

Milli Unit (10

−3

, one thousandth)

Specifications

Display: 10000 count display with backlight

Overrange: (OL) or (-OL) is displayed

Measurement rate: 2 times per second, nominal

Zero: Automatic

Operating environment: 32°F to 122°F (0°C to 50°C) at <70%

relative humidity

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH

(with battery removed)

Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH

Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to

18°C (32°F to 64°F), 28°C to 50° C(82°F to 122°F)]

APO (Auto Power Off): Approx. 30 minutes

Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22

Battery life: 100 hours typical alkaline

Low battery indication: Battery icon will be empty (

). "batt"

displays along with a continuous beep when the battery voltage

drops below the operating level. Meter shuts off in 5 seconds.

Dimensions: 258.3mm(H) x 71.2mm(W) x 42.7mm(D)

Weight: Approx. 278g including battery

Altitude: 6562 feet (2000m)

Overload protection: 600VDC or 600VAC rms unless otherwise

stated in the individual test sections.

Test leads: Shall use UL listed test leads complied UL61010-031

rated CATIII 600V or above.

Functions

Voltage AC (VAC) (50Hz-400Hz)

Test power lines (120, 220, 480), test 24V going to controls, and

test for transformer failure.

Ranges: 0 to 600V Resolution: 0.1V

Accuracy: ±(1.0% + 5 dgts) 50-100Hz

±(6%+5 dgts) 100-400Hz

True RMS: Yes Crest factor: ≤ 3

Input impedance: 1MΩ

Voltage DC (VDC)

Select VDC to measure DC voltage.

Ranges: 0 to 600V

Accuracy: ±(1.0% + 5 dgts) on 600V range

Resolution: 0.1V Input impedance: 1MΩ

MilliVolt DC (mVDC)

Select the mVDC range to display measurements from any

Fieldpiece accessory head. See Modular Expandability section on

reverse page for more details.

Ranges: 1000mV and 10000mV

Accuracy: ±(0.5% + 5 dgts)

Resolution: 0.1mV or 1mV Input impedance: 1MΩ

MicroAmps DC (µADC)

Microamps for flame rectifier diode test on a heater control.

Connect leads between flame sensor probe and control module and

turn heating unit on to read µA measurement. When the flame is on,

there should be a measurable µADC signal, typically under 10µADC.

Compare measurement to manufacture’s specification to determine if

replacement is necessary.

Ranges: 1000µA Resolution: 0.1µA

Accuracy: ±(1.0% + 5 dgts) Voltage burden: 1V

Overload Protection: 600VDC or 600VAC rms

Frequency (Hz) Through Leads

Check variable frequency drives. Check incoming voltages to

ensure they are cycling at 60Hz or desired frequency. Select VAC/Hz

and press SEL button.

Ranges: 20 to 400Hz Resolution: 0.1Hz

Accuracy: ±(0.5% + 5)

Sensitivity: 5V rms on VAC range.

Capacitance (MFD)

Capacitors are one of the most failure prone components in

a HVAC/R system. Set to MFD/Ω/

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

to test motor start and run

capacitors. Discharge the capacitor and disconnect from power and

resistors between terminals before testing.

Ranges: 0 to 1000µF Resolution: 0.1µF

Accuracy: ±5% + 15 dgts

Overload Protection: 600VDC or 600VAC rms

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

SC57

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SC57

O

F

F

WIRELESS ENABLED

SEL

HOLD

HOLD

MAX

MIN

SYNC

SYNC

MAX

MIN

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

O

F

F

O

F

F

O

F

F

Discharge Cap First!

O

F

F

SC54

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

O

F

F

SEL

HOLD

HOLD

MAX

MIN

MAX

MIN

SYNC

MAX

MIN

O

F

F

SC54

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

O

F

F

SEL

HOLD

HOLD

MAX

MIN

MAX

MIN

SYNC

MAX

MIN

O

F

F

SEL

RNG

Air Velocity

& Temperature

Head

English

READ

LO BATT

ON

LCD X

100

Average

(16 sec)

Metric

Real

time

AAV3

AUTO-

OFF

English

Metric

Ft/min

M/s

KM/hr

MPH

ºF

ºC

OFF

O

F

F

This manual is related to the following products: