Universal Switch Panel (USP) User Manual

39 OF 41

d) Group A-H

Setting the operating mode to GROUP 'x'
will cause the 'y' GPO state to turn on
when the 'Y' switch is pressed and cause
all the other GPO states, that are assigned
to the 'x' group, to turn off.




Assign switches 1, 2, 3, 4 to group 'x'.
Press switch 2 - GPO 1, 3, 4 stays off or goes off, GPO 2 goes on.
Press switch 1 - GPO 2, 3, 4 stays off or goes off, GPO 1 goes on.
Press switch 3 - GPO 1, 2, 4 stays off or goes off, GPO 3 goes on.
Press switch 4 - GPO 1, 2, 3 stays off or goes off, GPO 4 goes on.

3)

MOMENTARY ON TIME (ADJUSTABLE FROM 10MS TO 2000MS IN 10MS

INCREMENTS)

This setting sets the time that the GPO state will remain on after the the
switch is pressed. This is only used for the MOMENTARY MODE.