DNF Controls Universal Switch Panel (USP-8, USP-8D, & USP-16) User Manual
Page 17
Universal Switch Panel (USP) User Manual
15 OF 41
C.
TALLY ASSIGNMENT
Use this page to assign operating mode, text legend, font size, and tally
color to each front panel switch. (This page is not available on USP-EM.)
Tally Assignment Table Parameters
Parameter
Description
Mode
STANDARD: Switch tally controlled by one GPI or GPO
ALARM: Switch tally controlled by more than one GPIs
ET: Switch tally controlled by multiple remote events from GTP-32
Alarm
If MODE= ALARM, select alarm group that will control switch tally
ON Text
Text displayed when Tally state is ON.
Text: Up to 18 ASCII characters (See ON Font selection below).
OFF Text
Text displayed when Tally state is OFF.
Text: Up to 18 ASCII characters (See OFF Font selection below).
ON Font
SMALL: Display 3 rows of 6 characters each. (Display 1st 18 characters)
NORMAL: Display 2 rows of 4 characters each. (Display 1st 8 characters)
BIG: Display 1 row of 3 characters. (Display 1st 3 characters)
OFF Font
SMALL: Display 3 rows of 6 characters each. (Display 1st 18 characters)
NORMAL: Display 2 rows of 4 characters each. (Display 1st 8 characters)
BIG: Display 1 row of 3 characters. (Display 1st 3 characters)
ON Color
Dark, Red, Green, Amber, Flashing Red, Flashing Green, Flashing Amber
OFF Color
Dark, Red, Green, Amber, Flashing Red, Flashing Green, Flashing Amber
Tally Source
LOCAL: Always ON, Always OFF, Follow GPO, GPI-1 through GPI-16.
REMOTE: Remote USP GPI, Remote USP GPO, GTP-32/DC20 event.
Remote Device
Select Remote Device Description from list.
(Only available when Tally Source= REMOTE).
Event Label
GTP-32 or DC20 Event Label. Must be an exact match of GTP or DC20
event label. (Only available when Tally Source= GTP32/DC20).