DNF Controls Universal Switch Panel (USP-8, USP-8D, & USP-16) User Manual
Page 32
30 OF 41 Universal Switch Panel (USP) User Manual
d) Click on the REBOOT USP TO TO CONFIGURE WITH NEW
SETTINGS link to complete the configuration of the USP.
e) Once the USP has rebooted, click on the HOME link to return to
the USP main page.
3.
FIRMWARE UPGRADES
The Universal Switch Panel is designed to allow field upgrades of its software quickly
and easily through a web browser. Please follow the firmware upgrade directions
provided with the software file.
4.
MANUALLY RESET FACTORY DEFAULT CONFIGURATION
For the purposes of troubleshooting, the Universal Switch Panel can be reset to its
factory default configuration using the buttons on the rear of the unit. NOTE: This
will reset the IP address to its default configuration (IP address 192.168.10.217,
subnet mask 255.255.255.0).
a) Hold down the Reset button on the rear of the USP.
b) Hold down the S1 button on the rear of the USP, and then
release the Reset button. This will cause the USP to reboot.
c) Continue to hold the S1 button down. The normal startup
message will be displayed, after which the display will go blank.
d) After the display goes blank, wait 10 seconds and then release
the S1 button. The USP will reboot.
e) Once the USP has completed its second reboot, it will be in its
factory default state, with the default IP address and subnet
mask.