beautypg.com

DNF Controls Universal Switch Panel (USP-8, USP-8D, & USP-16) User Manual

Page 25

background image

Universal Switch Panel (USP) User Manual

23 OF 41

G.

GPO CONFIGURATION

Use this page to configure the operation of the local GPOs. If the GPOs
are not used, this page may be left blank.

GPO Configuration Table Parameters

Parameter

Description

User Defined

ON State

RELAY OPEN: When the GPO is ON, the relay is OPEN. When the

GPO is OFF, the relay is CLOSED.

RELAY CLOSED: When the GPO is ON the relay is CLOSED. When

the GPO is OFF, the relay is OPEN (Factory Default).

Operating
Mode

MOMENTARY:

The GPO turns ON, waits for the MOMENTARY ON TIME to
expire, and then automatically turns OFF.

LATCH:

The GPO turns ON and stays ON. The GPO turns OFF and stays

OFF.

FOLLOW:

The GPO follows the switch. The GPO turns ON when the

controlling switch is held pressed and immediately turns OFF
when the controlling switch is released.

ALARM:

The GPO turns ON when any alarm is active or has not been
cleared. It will turn OFF only when all alarms have been
cleared.

GPO GROUP (Radio Groups RG1 – RG8):

Only one GPO in a GPO Group can be ON at any time. When a
GPO is turned ON, all of the other GPOs in the group are
immediately turned off.

FLIP-FLOP (LatchFF1–LatchFF8 & MomentaryFF1–Momentary FF8):

Only two GPOs can be assigned to one Flip-Flop group. Like a
GPO Radio Group, when one GPO turns ON the other
automatically turns OFF.

LATCHFF: The GPO turns ON and stays ON. The GPO turns OFF

and stays OFF.

MOMENTARYFF: The GPO turns ON, waits for the MOMENTARY

ON TIME to expire, and then automatically turns
OFF.

Momentary

ON Time

For MOMENTARY operating mode only. ON duration for Momentary
GPO. Settable from 0.01 sec to 2.0 sec.