Universal Switch Panel (USP) User Manual
13 OF 41
B.
SWITCH ASSIGNMENT
Use this page to assign a function (action) to each of the the USP’s front
panel switches. If the front panel switches will not be used, this page
may be left blank.
Switch Assignment Table Parameters
1)
Click on the Switch Assignment Button. The Switch Assignment Page will be
displayed.
2)
Click on the drop down arrow in each column to view the list of available
options/ values. Select the desired option/ value by clicking on it.
3)
Select the switch number in the Switch column.
Parameter
Description
Switch
Select the desired switch number. One switch can be configured to support
more than one function. A total of 40 switch assignments are supported.
Remote Device
Select the remote device to notify when the front panel switch is pressed or
released. (Only active when TYPE is not LOCAL)
Type
Local: Control GPO on this USP
Remote USP: Control GPO on remote USP
GTP32/DC20: Send switch ‘pressed’ or ‘released’ notification to remote
GTP32 or DC20
Radio Group
Not used at this time. See GPO Configuration- Operating Mode for
configuring Radio Groups.
GPO
Assign GPO controlled by switch.
ENABLE
SWITCH
Assign one of the front panel switches as the ENABLE switch. All switch
presses will be ignored until the ENABLE switch is first pressed and held.
DISABLE ALL
SWITCHES
Disable all switches. Use USP as a tally annunciator panel only.