St300 setup defaults – DNF Controls 2034CL-N-PBIO User Manual
Page 22
22 2034CL-N, 300 Clip Instant Access System, NATIVE Protocol with PBIO Option
ST300 SETUP DEFAULTS
RECORD
Lockout
CHANNEL, CONNECTOR
ASSIGNMENT
CN1 for all. CHA, CHB, CHC, CHD respectively.
RECORD
RECORD = [REC] Only
RECALL MODE
Normal
LEARN MODE
Normal mode
MARK-Q
CURRENT Cue Point
TAPE TIME
NDF
STOP MODE
PB
WIND MODE
LATCH
SWITCHER TYPE
GVG
PARITY
ODD
SLOMO with
Wheel
MAX SHUTTLE
8 X
DATA PORT
CN3
AUTO ALIGNMENT
OFF
NOTE: The directory chosen in the MENU will be the directory selected upon reset.
If the Profile’s working directory is changed by other programs, when the ST300 starts it will
change to the directory last chosen from the menu.
When installing an upgrade eprom:
Clear the Cue Point memory
Set factory defaults
Set the directory
Then, reenter the CLIP IDs at the appropriate Cue Points or download them from a PC to which
the list has been previously saved, using the Transfer Utility or Operator’s Suite.
Also, enter into the MENU any changes from the default settings. Failure to follow this procedure
may lead to corruption of the Clips and unpredictable operation.