View content of cue points on the st300, Transfer cuelist, A. transmit cue list function – DNF Controls 2034CL-N-PBIO User Manual
Page 16
16 2034CL-N, 300 Clip Instant Access System, NATIVE Protocol with PBIO Option
14. VIEW CONTENT OF CUE POINTS ON THE ST300
a.
Select the VTR to examine the contents of a Cue Point by pressing [1], [2] or [3].
b. Press
[NEXT CUE] or [LAST CUE] to step through the Cue Points
OR
Enter a 1-, 2- or 3-digit number on the numeric keypad, followed by [ENTER].
The contents of the selected Cue Point are shown on the bottom line of the display.
15. TRANSFER
CUELIST
The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a PC, using
the provided utility software on the PC, or to another ST300. Transfer to a PC requires OpSuite
3.0 software, which runs on a Windows-based computer. Contact DNF Controls for more
information.
a.
TRANSMIT CUE LIST FUNCTION
1)
TO TRANSMIT CUE POINTS TO THE ST300
a)
Connect the VTR4 connector on the rear of the ST300 to the VTR4
connector of the receiving ST300 using an RS422 9-pin cable with TX
and RX lines crossed.
(A “turnaround” cable)
b) Press
[MENU] and scroll the Wheel to “Transmit CUE List?
YES=Enter, Exit=ESC”
c) Press
[ENTER] to start transmitting.
The Display shows “Waiting to transmit” on the first line.
d)
When the Receiver is ready, transfer starts automatically.
The Display now shows “Transmitting cuelist.”
e)
After the transfer is over, the display shows “Transfer is over” for one
second and then shows “Waiting to transmit” again.
f)
Connect another ST300 to transmit the list again.
OR
Press [ESC] twice to exit the MENU mode.
2)
TO TRANSMIT CUE POINTS TO THE PC
a)
Connect the VTR4 connector on the back of the ST300 to one of the
COM ports on the PC using a RS422 to RS232 adapter.
b)
Repeat steps b-f of the TRANSMIT CUE POINTS to the ST300
section.
The RECEIVE CUELIST function allows you to receive your list of Cue Points
from a PC or from another ST300.