48

International Installation

2. Route the cable through conduit to the back of the display. Use the

3

/

4

" knockout for

access, careful not to damage internal components.

3. Remove the cover of the power termination panel.
4. Connect the neutral wire to the neutral lug and the live wire to the Line 1 lug. The

ground wire connects to the grounding bus bar.