beautypg.com

Section 3: power installation, 1 conduit, 2 overview of power connection – Daktronics Galaxy AF-3500 Series 46 mm User Manual

Page 13: 3 power requirements, Section 3, Power installation, Conduit, Overview of power connection, Power requirements

background image

Power Installation

9

Section 3:

Power Installation

Only a qualified individual should terminate power and signal cable to a Daktronics display.
Daktronics engineering staff must approve all proposed changes, or the warranty will be void.

3.1 Conduit

Daktronics does not provide conduit. Separate conduit must be used to route:

Power

Signal-in wires to the signal termination enclosure (when applicable).

Signal-out wires (if not using the provided interconnect cable).

For power, displays come with either a J box, or a

3

/

4

" conduit access hole located near the

lower-right corner, on the back of the display. For signal, displays come with either signal
input quick-connects, or etched drilling guides for conduit.

3.2 Overview of Power Connection

Terminate display power either at the J box, or internally, at the power termination panel.
Refer to Section 3.5 for wiring examples.

Route power to the display through a fused disconnect switch, which can open all
ungrounded power conductors. Refer to Section 3.3 for additional information.

Install the disconnect switch within sight of display maintenance personnel, unless it can
be locked in the open position. Refer to Section 3.3 for additional information.
Note: Displays are equipped with circuit breakers that carry a UL489 or UL1077 (IEC
60947
, VDE 660) rating. These devices protect only the components within the display.

Follow local code specifications when routing power conductors from the disconnect
switch to the display.

Connect the grounding conductor to the grounding lug on the back of the display. Refer
to Section 3.4 for additional information.

For sectional displays, each section has its own power termination panel. Display lengths
of 208, 224, 240, and 256 are two sections shipped as one; therefore, the installer will have
to bring power to each assembled section.

3.3 Power Requirements

Install the display according to applicable local and national electrical codes. This
includes proper grounding and bonding of the display.

Displays use single-phase power.

Do not connect the displays to any voltage other than that listed on the Daktronics
product label.

Proper power installation is imperative for display operation.

Refer to Appendix B: for the power specifications of the various display sizes.
Note: For circuit conductors delivering power to a display, size them according to local
and national electrical codes, so the power distribution system delivers full load power to
the display while maintaining a voltage within five percent of the nominal utility voltage.