beautypg.com

Appendix c: international installation, Appendix c, International installation – Daktronics Galaxy AF-3500 Series 46 mm User Manual

Page 51

background image

International Installation

47

Appendix C:

International Installation

Terminating Hot, Neutral, and Ground Wires at the J box

1. Route the power cable through conduit to the rear of the display and into the power

termination J box.

2. The power termination enclosure will contain two wires plus a ground coming from the

interior of the display. These wires are pre-terminated to the power termination panel
inside the display.
Note: The following colors are used for the pre-terminated wires:

240 VAC

Line 1

Brown

Neutral

Blue

Ground

Green/Yellow

3. Inside the display’s external power termination J box, connect the power wires to the

wires coming from the display interior using wire nuts. Refer to Figure 40.

Terminating Single-Phase Power to the Internal Power Termination
Panel

Daktronics displays used for international applications are equipped with different power
termination panels than domestic displays. However, the termination method is similar to
the domestic termination discussed in Section 3.5.

1. Open the display as explained in Section 6: and locate the power termination panel.

Figure 40: 240 V Power Termination