Safety
Read all instructions and warnings before using.
Important Voltage Information
Before plugging the power cord into an electrical outlet, verify that the voltage requirements for the
site match the voltage of the treadmill that has been received. The power requirements for the Cybex
770T Treadmill include a grounded, dedicated circuit, rated for one of the following:
•
100 VAC, 50/60 Hz, 20A
•
115 VAC, 50/60 Hz, 20A
•
208 VAC, 60 Hz, 15A
•
220 VAC, 60 Hz, 15A
•
230 VAC, 50 Hz, 13A, UK
See the front warning decal for the voltage requirements of the treadmill.
Grounding Instructions
This treadmill must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
WARNING: Shock and electrocution hazard.
•
Connect unit to a grounded outlet.
•
Do not use voltage adapter or extension cord.
This treadmill is for use on a grounded, dedicated circuit. Make sure that the treadmill is connected to
an outlet having the same configuration as the plug. Do not use a ground plug adapter to adapt the
power cord to a non-grounded outlet.
115 VAC
Euro Plug
220 VAC
UK
Danish
Australia
NEMA 5-20
CEE 7/7
NEMA 6-15
230 VAC
107-2-D1
AS/NZS 3112