Testing operation – Cybex 770A Arc Trainer User Manual
Page 60

60
Cybex Owner’s Manual
Testing Operation
Use the following instructions to test the full resistance and incline range of the unit:
1. Plug the optional power cord into a power outlet from a grounded circuit, See Electrical
Requirements. Coil up the remainder of the power cord and place it out of the way. If you do
not have the optional power supply, skip to step 3.
2. Verify the control panel will illuminate and is in Dormant Mode.
3. Hold the handrails to steady self while stepping into the foot plates.
4. Begin striding.
5. Verify lower heart rate cable is not rubbing on handle during operation.
6. Tap QUICK START icon on the CardioTouch screen.
7. Run unit through full resistance range. First press the RESISTANCE + key until unit reaches
its highest load (the display will show “100”). Then press the
RESISTANCE - key until unit
reaches its lowest load (the display will show “0”).
When unit reaches the set incline and resistance, the displays will stop flashing and remain steadily
illuminated to indicate the desired settings have been reached.
8. Run unit through full incline range. First press the INCLINE key until the unit reaches its
highest incline (the display will show “20”). Then press the
INCLINE key until unit reaches its
lowest incline (the display will show “0”).
WARNING: Serious injury or death can occur. To avoid injury or death the following
procedure must be followed. Wait until all moving parts come to a complete
stop before dismounting. Failure to wait for complete stop can trip or injure
user.
9. Press STOP twice to bring the incline back to its start position, end the workout review, and
return the display to Dormant Mode.
10. Wait until foot plates come to a complete stop before dismounting unit. Hold handrails to
steady self while stepping off unit.