MBT-4000B Multi-Band Transceiver System

Revision 1

Appendix B

MN/MBT4000B.IOM

B–3

Figure B-1 illustrates a typical Dual-Base (Chain) Redundancy configuration. The two MBT-4000B

base units cooperate in monitoring the health of the two BUCs, two external amplifiers, two

Low-Noise Block Down Converters (LNBs), and each other. In case of a fault on an online

BUC/amplifier or LNB, the MBT-4000B base containing the corresponding standby chain will

automatically switch over to the standby chain in accordance with the following rules:

1. In dual-base (chain) redundancy operation, the redundancy is ‘slot’ based. The

corresponding pairs reside in the same ‘slot’ of the opposite MBT-4000B base, the pair

of BUCs connected to the “J3 | UNIT 1 COMM” (Slot 1) connector on each base form a

redundant pair. The LNBs connected to the “J12 | L-BAND IN” connector on each base

form the other redundant pair.

2. The corresponding BUCs in a pair must be of the same band type.

3. The Redundancy Interlink Cable (CEFD P/N CA/WR11224-1 or equivalent) must be

installed.

4. Base unit identification (MBT1 or MBT2) is driven by the redundancy interlink cable.

Hard-wired connections within the cable designate one MBT-4000B base as MBT1 and

the other as MBT2. The cable is labeled accordingly.

5. The RF and IF switches connected to MBT1 correspond to the redundant pair of BUCs

installed on the “J3 | UNIT 1 COMM” (Slot 1) connector.

6. The RF and IF switches connected to MBT2 correspond to the redundant pair of LNBs

installed on the “J12 | L-BAND IN” connectors.

7. When a BUC or LNB attached to MBT1 is online, the corresponding RF and IF switches

will be switched to Position A. When a BUC or LNB attached to MBT2 is online, the

corresponding switches will be switched to Position B.

For a switchover to occur:

1. Both MBT-4000B base units must be set to Redundancy Mode 2. The RED=2 remote

command must have been received by each base.

2. Both chains must be set to Automatic Mode. For example, if the redundant pair is on

Slot 2 of the bases, the RAM=21 remote command must have been received by each

base.

3. The corresponding standby chain must not be in faulted state.