A.2.2 Configurable Summary Faults

Configurable Summary Faults operate the same as Summary Faults, except Configurable

Summary Faults may be enabled or disabled using remote commands.

Table A-3. MBT-4000B Configurable Summary Faults

Mnemonic

Mute

Description

AUXCOM1

Slot 1 The IO1A/FAULT input (AUX COMM 1) indicates a fault. Monitoring for this fault is

enabled using the EAM command.

LNACUR2

Slot 2

The +17 V nominal bias tee provided LNB power supply current has exceeded the

maximum limit of 450 mA and has been disabled. The LNB power supply – and thus

this fault – is enabled using the LCS command.

This fault is cleared by a LCS command or power cycle.

LNAWIN2

Slot 2

The +17 V nominal bias tee provided LNB power supply current is outside the

programmed window. (The power supply is not disabled in response to this fault.). LNB

current window monitoring is configured and enabled using the LCS, CLC and LCW

commands.

This fault is cleared by an LCS command, CLC command, LCW command or power

cycle.

REF LD

All

The External Reference Monitor has lost lock with the external reference signal. The

attached converter has been muted. Monitoring for this fault is enabled using the XRF

command.

This fault is cleared when lock has been regained.