beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 71

background image

MBT-4000B Multi-band Transceiver System

Revision 1

Serial-based Remote Product Management

MN/MBT4000B.IOM

6–19

Parameter

Type

Command

(Instruction Code

and qualifier)

Valid on

MBT or

BUC/BDC

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e., ASCII codes

between 48 and 57)

Response to Command

(Target to Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Reference

Oscillator Adjust

REF=xxxx

MBT

4 bytes,

numeric

Command or Query.

Sets or returns Ref Osc Adjust in the form xxxx, where:

xxxx=value from 0000 to 0255, resolution=0001.

Example: REF=0197

Note: REF cannot be adjusted when the unit is locked to an external

reference source.

REF=

REF?

REF*

REF?

REF=xxxx

(same format as

command

arguments)

Retrieve

Equipment Type

N/A

All

22 bytes,

alphanumeric

Query only.

Unit returns a string indicating the Model Number and the software version

installed

Example: RET=BUC-4000 VER:1.0.3

N/A

RET?

RET=x….x

(see Description of

Arguments for

details)