MBT-4000B Multi-Band Transceiver System

Revision 1

Appendix A

MN/MBT4000B.IOM

A–2

A.2

Faults/Events

There are three types of Faults/Events that may occur and be recorded in the event log of the

MBT-4000B or BUC-4000:

Summary Faults

Configurable Summary Faults

Informational Events.

Each of these are described in further detail in the next

subsections; Tables B1 through B6 list possible

Fault/Event messages where applicable. An example of

a faulted system is shown in Figure A-2; here, Unit 2

has faulted.

Figure A-2. Faulted System Example

A.2.1 Summary Faults

Summary Faults indicate improper operation. When a Summary Fault condition occurs, the

Summary Fault Relay will be de-energized. If a Summary Fault occurs on a converter, it will

mute. If a Summary Fault occurs on the base unit, the converter will be muted according to the

specific error. If a Summary Fault occurs on the online unit of a redundant pair, the offline unit

will detect the fault and assume online state. In all cases, a corresponding event message will be

added to the event log.

Table A-1. MBT-4000B Summary Faults

Mnemonic

Mute

Description

15V PS1

All

The 15 volt power supply is out of tolerance.

28V PS1

All

The 28 volt power supply is out of tolerance.

5VT PS1

All

The 5 volt power supply is out of tolerance.

7V5 PS1

All

The 7.5 volt power supply is out of tolerance.

IIC BUS

All

Unable to communication via the internal high speed communication bus

Table A-2. BUC-4000 Summary Faults

Mnemonic

Description

15V SUP

The 15 volt power supply is out of tolerance.

5VT SUP

The 5 volt power supply is out of tolerance.

7V5 SUP

The 7.5 volt power supply is out of tolerance.

OVR TMP

The maximum operating temperature has been exceeded.

PLL LD

The PLL has lost lock.