Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Set RTC Time
TIM=hhmmss
All
6 bytes, numeric Command or Query.
Sets or returns the time, indicating the time from midnight, in the form
hhmmss where:
hh=hours, between 00 and 23
mm=minutes, between 00 and 59
ss=seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds
from midnight.
TIM=
TIM?
TIM *
TIM?
TIM=hhmmss
(same format as
command
arguments)
Retrieve Number
of unread
Stored Alarms
N/A
All
2 bytes, numeric Query only.
Returns the number of Stored Events that remain unread, in the form xx.
Example reply: TNA=18
N/A
TNA?
TNA=xx
(see Description of
Arguments for
details)
Terminal Status
Change
N/A
All
1 byte, numeric Query only.
Returns the status of the Terminal Status in the form x, where:
x=0 (no change in status) or 1 (change in status)
Example: TSC=0
N/A
TSC?
TSC=x
(see Description of
Arguments for
details)
External
Reference Fault
Logic
XRF=x
MBT
1 byte, numeric Command or Query.
Sets or returns enabling/disabling the software monitoring of the external
reference source in the form x, where:
x=0 (Ext Reference not monitored) or 1 (Ext Reference is monitored and
the lock state reported)
Note: If enabled and no source is present, a fault will be reported.
Example: XRF=1
XRF=
XRF?
XRF?
XRF=x
(see Description of
Arguments for
details)