MBT-4000B Multi-band Transceiver System

Revision 1

Serial-based Remote Product Management

MN/MBT4000B.IOM

6–20

Parameter

Type

Command

(Instruction Code

and qualifier)

Valid on

MBT or

BUC/BDC

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e., ASCII codes

between 48 and 57)

Response to Command

(Target to Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Retrieve

Maintenance

Status

N/A

All

103 bytes (MBT),

98 bytes (BDC),

98 bytes (BUC),

alphanumeric

Query only.

Used to Query the maintenance status of the unit.

Example for MBT-4000B base:

>0001/RMS={cr}{lf}

15VT1=015.1{cr}

7V5T1=007.7{cr}

5VLT1=005.0{cr}

28VT1=027.2{cr}

REFVT=001.3{cr}

LNA_1=000.0{cr}

LNA_2=000.0{cr}

RFSWP=B{cr}

IFSWP=N{cr}

RRFSW=B{cr}

RIFSW=B{cr}{lf}

Example for BUC: <0001A2/RMS={cr}

>0001A2/RMS={cr}{lf}

15VT=015.1{cr}

7V5T=007.6{cr}

5VLT=005.2{cr}

REFV=XXX.X{cr} (reserved for future use)

SYNT=007.2{cr}

POUT=XXX.X{cr} (reserved for future use)

TEMP=+25.0{cr}{lf}

Example for BDC: <0001A1/RMS={cr}

>0001A1/RMS={cr}{lf}

15VT=015.1{cr}

7V5T=007.6{cr}

5VLT=005.2{cr}

REFV=XXX.X{cr} (reserved for future use)

SYNT=007.2{cr}

LNAC=255.0{cr}

TEMP=+25.0{cr}{lf}

Note: “REFV” will show tuning voltage of reference OSC for standalone.

Otherwise REFV=xxx.x which means Not Applicable.

N/A

RMS?

RMS=x….x

(see Description of

Arguments for

details)