beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 70

background image

MBT-4000B Multi-band Transceiver System

Revision 1

Serial-based Remote Product Management

MN/MBT4000B.IOM

6–18

Parameter

Type

Command

(Instruction Code

and qualifier)

Valid on

MBT or

BUC/BDC

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e., ASCII codes

between 48 and 57)

Response to Command

(Target to Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Retrieve

Configuration

Status

N/A

All

65 bytes (MBT),

98 bytes (BDC),

76 bytes (BUC),

alphanumeric

Query only.

Returns the configuration status of the unit

Example for MBT-4000B base:

<0001/RCS?{cr}

>0001/RCS={cr}

BF1=X {cr}

BF2=X {cr}

BT1=DN{cr}

BT2=UP{cr}

RED=0{cr}

RAM=00{cr}

MBT=N, A, or B

EXT=0{cr}{lf}

Example for BUC/BDC:

<0001A1/RCS?{cr}

>0001A1/RCS={cr}

FLO=06300{cr}

ATT=01.00{cr}

MUT=1{cr}

SLP=0.3{cr}

LCS=0{cr}

LCW=99{cr}

LFL=1{cr}

REF=XXXX{cr} (reserved for future use)

XRE=X{cr} (reserved for future use)

AFR=0{cr}{lf}

Note: For BUC – LCS, LCW, & LFL will not be shown.

N/A

RCS?

RCS=x….x

(see Description of

Arguments for

details)

Redundancy

State

RED=x

MBT

1 byte

Command or Query.

Controls redundancy state in the form x, where:

x=0 (Off),

1 (Enables redundancy using single base unit), or

2 (Enables redundancy using dual base units)

Example: RED=1

RED=

RED?

RED*

RED?

RED=x

(same format as

command

arguments)