beautypg.com

Comtech EF Data MBT-4000B User Manual

Page 73

background image

MBT-4000B Multi-band Transceiver System

Revision 1

Serial-based Remote Product Management

MN/MBT4000B.IOM

6–21

Parameter

Type

Command

(Instruction Code

and qualifier)

Valid on

MBT or

BUC/BDC

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e., ASCII codes

between 48 and 57)

Response to Command

(Target to Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Serial Number

N/A

All

9 bytes, numeric Query only.

Returns the unit’s 9 digit serial number. Slave returns its S/N, in the form

xxxxxxxxx.

Example: RSN=000000165

N/A

RSN?

RSN= x….x

(see Description of

Arguments for

details)

Retrieve

Utility Status

N/A

MBT

24 bytes,

alphanumeric

Query only.

Returns the utility status of the MBT-4000B base unit..

Example:

<0001/RUS={cr}

>0001/RUS={cr}{lf}

ADR=0001{cr}

BDR=9600{cr}{lf}

N/A

RUS?

RUS=x….x

(see Description of

Arguments for

details)

Remote Baud

Rate

SBR=xxxx

MBT

4 bytes,

Command or Query.

Sets or returns the remote baud rate as follows: in the form xxxx, where:

9600=9600 baud

19K2=19200 baud

SBR=

SBR?

SBR!

SBR?

SBR=xxxx

(same format as

command

arguments)

Summary Fault

Status

N/A

All

N/A

Query only.

Returns the status of the Summary Fault Relay in the form x, where:

x=0 (OK) or 1 (FLT)

Example: SFS?

N/A

SFS?

SFS=x

(see Description of

Arguments for

details)

Remote Address SPA=xxxx

MBT

4 byte, numeric Command or Query.

Sets or returns the Physical Address of the MBT-4000B base unit in the

form xxxx, where:

xxxx=an address from 0001 to 9999, resolution=0001

Example: SPA=0412

SPA=

SPA?

SPA!

SPA?

SPA=xxxx

(same format as

command

arguments)

Slope Adjust

SSA=x.x

BDC

BUC

3 bytes, numeric Command or Query.

Sets or returns the Slope adjust level in the form x.x, where:

x.x=valid number from 0.0 to 1.0, resolution=0.1

Example: SSA=0.3

SSA=

SSA?

SSA*

SSA!

SSA?

SSA=x.x

(same format as

command

arguments)

Set Redundancy

Switch

SSW=xy

MBT

2 bytes,

alphanumeric

Command only.

Sets the switches dedicated to Slot 1 or 2, and sets them to either Port A

or Port B in the form xy, where:

x =1 (Slot 1) or 2 (Slot 2)

y=A (Switched to Converter on MBT_A) or B (Switched to Converter on

MBT_B)

SSW=

SSW=xy

N/A

SSW=xy

(same format as

command

arguments)