beautypg.com

6 optional message arguments, 7 end of packet – Comtech EF Data MBT-4000B User Manual

Page 58

background image

MBT-4000B Multi-band Transceiver System

Revision 1

Serial-based Remote Product Management

MN/MBT4000B.IOM

6–6

6.2.4.6 Optional Message Arguments

Arguments are not required for all messages. Arguments are ASCII codes for the characters 0 to 9 (ASCII codes 48 to 57), period (ASCII

code 46) and comma (ASCII code 44).

6.2.4.7 End of Packet

Controller-to-Target: This is the 'carriage return' character (ASCII code 13).

Target-to-Controller: This is the two-character sequence 'carriage return' (ASCII code 13), and 'line feed' (ASCII code 10).

Both indicate the valid termination of a packet.