beautypg.com

4 performing the ftp upload procedure – Comtech EF Data MBT-4000B User Manual

Page 49

background image

MBT-4000B Multi-band Transceiver System

Revision 1

Updating Firmware

MN/MBT4000B.IOM

5–9

5.4

Performing the FTP Upload Procedure

To proceed with the firmware update procedure, assumptions are made that:

The MBT-4000B is connected to a user-supplied, Windows-based PC:


o

The PC serial port is connected to the MBT4000B’s ‘J2 |COMM’ port using

the appropriate adaptive cabling.

o

The PC is running a terminal emulation program (for operation of the

MBT-4000B Serial Interface).

The latest firmware files have been downloaded or otherwise received from

Comtech EF Data and are available on the User PC in an accessible temporary

folder.

Step Task

1

Double-click FLSHCSAT.EXE

(filename or icon) to execute the

FTP upload utility.

2

From the FLSHCSAT window,

select the pertinent serial port

used for communication between

the User PC and the MBT-4000B

(Item ‘A’ in this example shows

that COM1 has been selected)

3

Do not select a baud rate (Item

‘B’) other than the default selection

of 38400, unless otherwise

instructed by Comtech EF Data

Technical Support.

4

Click [Software Upload] (Item ‘C’)

5

You are prompted to select a file

to upload. Click [Choose File].

Then, from the dialogue window

that opens, use the drop-down list

to select the drive (if needed), and

then navigate to the temporary

folder created earlier. Finally,

double-click on the firmware file

from the window to the left.