Comtech EF Data HPOD User Manual
Page 83

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
MN/HPOD.IOM
Serial-Based Remote Product Management
Revision 8
5–13
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Concise Utility
Status
N/A
11 bytes,
alphanumeric
Query only.
Reports the Maintenance status of the unit. Response is comma delimited in the form aaaa,bbbb,ccc,’cr’’lf’
where:
aaaa = Remote Unit Address
bbbb = Remote Baud Rate
N/A
CUS?
CUS=x….x
(See Description of
Arguments)
Set RTC (Real-
Time-Clock)
Date
DAT=
6 bytes,
numeric
Command or Query.
Set clocks in the form mmddyy, where:
mm = month of the year, between 01 and 12
dd = day of the month, between 01 and 31
yy = year, between 00 and 96 (2000 to 2096)
Example:(date = April 24, 2003):
<1/DAT=042503’cr’
>0001/DAT=’cr’’lf’
DAT=
DAT?
DAT*
DAT?
DAT=xxxxxx
(See Description of
Arguments)
Retrieve
Firmware
Number
N/A
256 bytes
Query only.
Returns the firmware type loaded into the unit.
Example: <1/FRW?’cr’
>0001/FRW=’cr’
BULK=FW12524’cr’
MnC =FW12522’cr’
FPGA=FW10788’cr’’lf’
Note: the RET? Query returns the MnC firmware revision.
N/A
FRW?
FRW=x…x
(See Description of
Arguments)
Mute State
MUT=
1 byte,
value of 0,1
Command or Query.
Mutes the unit, in the form x, where:
0 = Disabled
1 = Enabled
2 = Unit muted due to discrete control lines. Query response only.
Example: MUT=1’cr’
MUT=
MUT?
MUT*
MUT?
MUT=x
(See Description of
Arguments)
Online Status
ONL=
1 byte,
value of 0, 1
Command or Query.
Online status (applies only to redundancy), in the form x, where:
0 = Disabled
1 = Enabled
Example: <1/ONL=1’cr’
>0001/ONL=’cr’’lf’
ONL=
ONL?
ONL*
ONL?
ONL=x