Comtech EF Data HPOD User Manual
Page 81

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
MN/HPOD.IOM
Serial-Based Remote Product Management
Revision 8
5–11
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Clear All Stored
Alarms
CAA=
None
Command only.
Clears all Stored Events:
Example:
<1/CAA=’cr’
>0001/CAA=’cr’’lf’
Note: This command takes no arguments.
CAA=
N/A
N/A
Concise Alarm
Status
N/A
25 bytes,
alphanumeric
Query only.
Reports the Alarm status of the unit. Response is comma delimited in the form a,b,c,d,e,f,g,h,I,j,k,I,m’cr’’lf’
where:
a thru k = 0 or 1
0 = OK
1 = FT
a = +24V Power Supply
b = +15V Power Supply
c = +10V-A Power Supply
d = +10V-B Power Supply
e = +7.5V Power Supply
f = +5V Power Supply
g = -5V Power Supply
h = Fan#1 State
i = Fan#2 State
j = Heatsink Temp
k = Shutdown
l = llC Status
m=Forward Power Alarm
N/A
CAS?
CAS=x….x
(See Description of
Arguments)
Concise
Configuration
Status
N/A
24 bytes,
alphanumeric
Query only.
Reports the summarized version of RCS. Response is comma delimited in the form aaaaa,b,c,d,e-
e,fffff,g,‘cr’ where:
aaaaa = attenuation in dB
b = RF power amplifier state
c = mute state
0 = unmuted
1 = muted
d = online status
e-e = redundancy state and mode
fffff = gain offset in dB
g = AFR
N/A
CCS?
CCS=x….x
(See Description of
Arguments)