Comtech EF Data HPOD User Manual
Page 64

HPOD C, X-, or Ku-Band High-Power Outdoor Amplifier
MN/HPOD.IOM
Ethernet-based Remote Product Management
Revision 8
4–16
•
Amplifier – Use the drop-down list to set the amplifier as On or Off.
•
Mute – Use the drop-down list to set the Mute function as Enabled or Disabled.
Click [Change Configuration] to save these settings, or click [Reset] to revert to the previously
assigned Amplifier settings.
Fault Recovery
Use the drop-down list to set Fault Recovery as Automatic or Manual, and then click [Change].
BUC Mute
Use the drop-down list to set BUC Mute as Muted or Not Muted, and then click [Change].
Reference Adjust
Enter a numeric value from 0 to 255 to set the reference oscillator tuning voltage. The default
voltage value is 87. Click [Change] when done.
Serial
• Remote Address – Enter a physical remote address from 0001 to 9999.
• Baud Rate – Use the drop-down list to set the operating baud rate as 9600 or 19200 bps.
Click [Change Serial Configuration] to save these settings.
- CDD-880 (124 pages)
- CDM-800 (130 pages)
- ODMR-840 (184 pages)
- CDM-750 (302 pages)
- CDM-840 (244 pages)
- SLM-5650A (420 pages)
- CTOG-250 (236 pages)
- CDM-700 (256 pages)
- CDM-760 (416 pages)
- CDM-710G (246 pages)
- CDM-600/600L (278 pages)
- CDMR-570L (512 pages)
- CDM-625 (684 pages)
- CDM-625A (756 pages)
- CDD-564A (240 pages)
- CDD-564L (254 pages)
- CLO-10 (134 pages)
- MCED-100 (96 pages)
- CDMR-570AL (618 pages)
- CDM-600 LDPC (2 pages)
- BUC Power Supply Ground Cable (2 pages)
- MPP70 Hardware Kit for CDM-570L (4 pages)
- MPP50 Hardware Kit for CDM-570L (4 pages)
- CDM-625 DC-AC Conversion (4 pages)
- CDM-625 DC-AC Conversion with IP Packet Processor (4 pages)
- DMDVR20 LBST Rev 1.1 (117 pages)
- DMD2050E (212 pages)
- DMD-2050 (342 pages)
- DMD1050 (188 pages)
- OM20 (220 pages)
- QAM256 (87 pages)
- DD240XR Rev Е (121 pages)
- MM200 ASI Field (5 pages)
- DM240-DVB (196 pages)
- MM200 (192 pages)
- CRS-150 (78 pages)
- CRS-280L (64 pages)
- CRS-170A (172 pages)
- CRS-180 (136 pages)
- SMS-301 (124 pages)
- CiM-25/8000 (186 pages)
- CiM-25 (26 pages)
- CRS-500 (218 pages)
- CRS-311 (196 pages)
- CIC-20 LVDS to HSSI (26 pages)