Comtech EF Data CRS-311 User Manual
Page 79
CRS-311 1:1 Redundancy Switch
Revision 7
Cables and Connections
MN/CRS311.IOM
3–31
3.3.6.3 Ethernet Router Mode Data Traffic via the Optional Network
Processor (NP) Interface
When the SLM‐5650/5605A modems are equipped with the optional multi‐port Network
Processor (NP) Interface Module, Multi‐Port Ethernet Router Mode is possible.
Referring to Figure 3‐20, connect and secure all PP/CAT5FF3FTGY CAT5 Data Cables as follows:
• From the RJ‐45 connectors labeled “Port 1” through “Port 4” on the RMI or TMI, to the
RJ‐45 connectors ports labeled “1” through “4” on the Redundant or Traffic Modem
optional Network Processor (NP) Interface Module.
3.3.6.4 Ethernet BPM Mode Data Traffic via the Optional Network
Processor (NP) Interface
Appendix E, Sect. E.3 Network Processor (NP) Interface BPM (Bridge Point‐to‐
Multipoint) Mode in the SLM‐5650A Satellite Modem Installation and Operation
Manual (CEFD P/N MN‐SLM5650A)
When the SLM‐5650/5605A modems are equipped with the optional multi‐port Network
Processor (NP) Interface Module, Ethernet BPM Mode is possible.
Referring to Figure 3‐21 , connect and secure all PP/CAT5FF3FTGY CAT5 Data Cables as follows:
• From the RJ‐45 connector labeled “Port 1” on the RMI or TMI, to the RJ‐45 connector
labeled “J5 Ethernet” port on the Redundant or Traffic Modem.
• From the RJ‐45 connectors labeled “Port 2”, “Port 3”, and “Port 4” on the RMI or TMI, to
the RJ‐45 connectors ports labeled “1”, “2”, and “3” on the Redundant or Traffic Modem
optional Network Processor (NP) Interface Module.