3 remote commands and queries – Comtech EF Data CRS-311 User Manual
Page 138

CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–8
• Target‐to‐Controller: This is the two‐character sequence ‘Carriage Return’, ‘Line Feed’ ([cr][lf]) (ASCII codes 13 and 10).
Both indicate the valid termination of a packet.
6.3
Remote Commands and Queries
The table that follows provides a ‘quick reference‘ to the Instruction Codes available at present for M&C of the CRS‐311. The ‘C’ and ‘Q’
columns, when marked with an ‘X’, denote whether that Instruction Code is Command Only, Query Only, or Command and Query.
Instr Code
C
Q
Page Note: The following codes are used in the ‘Response to Command’ column:
AAM
X X 7-9
Code
Meaning
ACT
X 7-9
=
Message OK
AMQ
X 7-9
BBU
X X 7-9
?
Received OK, but invalid arguments found
BKH
X X 7-9
CAE
X 7-10
*
Message OK, but not permitted in Current mode
CLD
X 7-10
CST
X X 7-10
#
Message OK, but only permitted in Remote mode
DAY
X X 7-10
EID
X 7-10
~
Timed out a pass-through message
FLT
X 7-11
IMS
X X 7-11
!
Unknown command
LRS
X X 7-11
MAM
X X 7-11
MOD
X 7-12
NUE
X 7-12
OPM
X X 7-12
RNE
X 7-12
RSH
X X 7-13
SAM
X X 7-13
SGC
X X 7-13
SID
X X 7-13
SNO
X 7-13
SWR
X 7-13
TIM
X X 7-14
XMI
X 7-14