2 object 6098h: homing_method (ds402), 6098h, Object 6098h: homing_method (ds402) – BECKHOFF AX2000 CANopen communication profile User Manual
Page 95: Canopen drive profile

4.16.4.2
Object 6098h: homing_method (DS402)
Index
0x6098
h
Name
homing_method
Object code
VAR
Data type
INTEGER8
Mode
hm
Access
rw
PDO mapping
possible
Unit
position units
Value range
-128 ... 127
Default value
0
EEPROM
yes
The following homing methods are supported:
Method as per
DSP402
Brief description: Homing
ASCII command
-128..-4
reserved
—
-3
move to mechanical stop, with zeroing
NREF = 7
-2
set reference point at present position, allowing for lag/following
error
NREF = 6
-1
homing within a single turn
(direction of rotation depends on distance)
NREF = 5, DREF= 2
0
reserved
—
1
homing to negative limit switch,
with zeroing, negative direction of motion
NREF = 2, DREF= 0
2
homing to positive limit switch,
with zeroing, positive direction of motion
NREF = 2, DREF= 1
3..7
not supported
—
8
homing to reference switch,
with zeroing, positive direction of motion
NREF = 1, DREF= 1
9..11
not supported
—
12
homing to reference switch,
with zeroing, negative direction of motion
NREF = 1, DREF= 0
13..14
not supported
—
15..16
reserved
—
17
homing to negative limit switch,
without zeroing, negative direction of motion
NREF = 4, DREF= 0
18
homing to negative limit switch,
without zeroing, positive direction of motion
NREF = 4, DREF= 1
19..23
not supported
—
24
homing to reference switch,
without zeroing, positive direction of motion
NREF = 3, DREF= 1
25..27
not supported
—
28
homing to reference switch,
without zeroing, negative direction of motion
NREF = 3, DREF= 0
29..30
not supported
—
31..32
reserved
—
33
homing within a single turn
negative direction of rotation
NREF = 5, DREF= 0
34
homing within a single turn
positive direction of rotation
NREF = 5, DREF= 1
35
set reference point at present position
NREF = 0
36..127
reserved
—
CANopen for AX2000/2500
95
BECKHOFF
07/2007
CANopen Drive Profile