Sub-index
12
h
Brief description
position absolut encoder in SI units
Unit
user units
Access
ro
PDO mapping
possible
Data type
INTEGER32
Value range
-(2
31
-1)..(2
31
-1)
Default value
—
Assuming that an absolute encoder has been configured in the device (EXTPOS 1, 2 or 3), this
Object can be used to determine the encoder position. Scaling is defined by parameters PGEARI,
PGEARO, ENCIN, and EXTMUL.
Sub-index
13
h
Brief description
Internal Position Setpoint
Unit
internal position counts
Access
ro
PDO mapping
possible
Data type
INTEGER32
Value range
-(2
31
-1)..(2
31
-1)
Default value
—
This Object can be used to read the position setpoint used for internal position control. The value is
output in internal position counts.
Sub-index
14
h
Brief description
Analog Input 1 actual value
Unit
mV (scaled)
Access
ro
PDO mapping
possible
Data type
INTEGER16
Value range
-(2
15
-1)..(2
15
-1)
Default value
—
This Object supplies a scaled value for the input voltage at analog input 1. In this context, 10 V cor-
responds to 8192 increments.
Sub-index
15
h
Brief description
Analog Input 2 actual value
Unit
mV (scaled)
Access
ro
PDO mapping
possible
Data type
INTEGER16
Value range
-(2
15
-1)..(2
15
-1)
Default value
—
This Object supplies a scaled value for the input voltage at analog input 2. In this context, 10 V cor-
responds to 8192 increments.