1 object 2030h: dp-ram-variables 9-16 (write only), 2 object 2090h: dp-ram-variables 1-8 (read only), 2030h – BECKHOFF AX2000 CANopen communication profile User Manual
Page 88: 2090h, Object 2030h: dp-ram-variables 9-16 (write only), Object 2090h: dp-ram-variables 1-8 (read only), Beckhoff

4.12
Freely available, mappable PLC variables, Objects 2030h / 2090h
Parameters DPRVAR1 .. DPRVAR16 enable status variables to be exchanged between the CAN
bus and internal PLC sequential program. Two sets of eight Objects - one for write-only (WO) and
one for read-only - are provided for this purpose (these Objects can also be mapped in PDOs).
4.12.1
Object 2030h: DP-Ram-Variables 9-16 (write only)
Index
2030
h
Brief description
DP-Ram Variables, write only (PDO)
Object code
ARRAY
Number of elements
9
Sub-Indexes:
Sub-index
01
h
...08h
Brief description
DP-Ram Variable 9...16
Unit
—
Access
rw
PDO mapping
possible
Data type
INTEGER32
Value range
INTEGER32
Default value
0
4.12.2
Object 2090h: DP-Ram-Variables 1-8 (read only)
Index
2090
h
Brief description
DP-Ram Variablen, nur lesbar (PDO)
Object code
ARRAY
Number of elements
9
Sub-Indexes:
Sub-index
01
h
...08h
Brief description
DP-Ram Variable 1...8
Unit
—
Access
ro
PDO mapping
possible
Data type
INTEGER32
Value range
INTEGER32
Default value
0
88
CANopen for AX2000/2500
CANopen Drive Profile
07/2007
BECKHOFF