4.15.4
Object Decription
4.15.4.1
Object 6063h: position_actual_value* (DS402)
The Object position_actual_value provides the momentary actual position in increments.
The resolution is 16 bits or 20 bits per turn (see PRBASE command).
Index
0x6063
h
Name
position_actual_value
Object code
VAR
Data type
INTEGER32
Mode
pc, pp
Access
rw
PDO mapping
possible
Unit
increments (1 turn = 16 bit / 20 bit)(see PRBASE)
Value range
(-2
31
) ... (2
31
-1)
Default value
—
EEPROM
no
4.15.4.2
Object 6064h: position_actual_value (DS402)
The Object position_actual_value provides the actual position. The resolution (manufacturer-speci-
fic units: see Objects 2020
h
08
h
/09
h
or as per drive profile DSP402: see Object 607A
h
) can be alte-
red by the gearing factors of the position controller.
Note: this Object should not be defined (mapped) in a synchronous TPDO.
Index
0x6064
h
Name
position_actual_value
Object code
VAR
Data type
INTEGER32
Mode
pc, pp
Access
rw
PDO mapping
possible
Unit
position units
Value range
(-2
31
) ... (2
31
-1)
Default value
—
EEPROM
no